Search results for "Spectral index"
showing 10 items of 64 documents
Jet-torus connection in radio galaxies
2017
High-resolution Very-Long-Baseline Interferometry observations of active galactic nuclei have revealed asymmetric structures in the jets of radio galaxies. These asymmetric structures may be due to internal asymmetries in the jet, could be induced by the different conditions in the surrounding ambient medium including the obscuring torus, or a combination of the two. In this paper we investigate the influence of the ambient medium (including the obscuring torus) on the observed properties of jets from radio galaxies. We performed special-relativistic hydrodynamic (RHD) simulations of over-pressured and pressure-matched jets using the special-relativistic hydrodynamics code \texttt{Ratpenat}…
Human cerebral microcirculation and oxygen saturation during propofol-induced reduction of bispectral index †
2011
† This study investigates the effects of propofol-induced changes in bispectral index (BIS) on cerebral microcirculation and oxygenation during craniotomies. † In 2 mm cerebral depth, an increase in propofol dosage resulted in increased oxygen saturation (srvO2 )w ithout reduction of capillary venous blood flow (rvCBF). † Difference in oxygen content (avDO2) and approximated cerebralmetabolicrateofoxygen (aCMRO2) decreased with an increase in propofol dosage in 2 mm cerebral depth. † Alterations in BIS showed no effect on rvCBF, srvO2 ,a nd haemoglobin amount (rvHb) or on avDO2 or aCMRO2 in 8 mm cerebral depth. † These findings suggest that the CBF/CMRO2 ratio is altered by propofol in a re…
Degree of Postictal Suppression Depends on Seizure Induction Time in Magnetic Seizure Therapy and Electroconvulsive Therapy.
2017
OBJECTIVES Anesthesia is required for both magnetic seizure therapy (MST) and electroconvulsive therapy (ECT), although it has anticonvulsant properties. In this case, bispectral index (BIS) monitoring, a specific electroencephalogram-derived monitoring, can be used to find the optimal seizure induction time during anesthesia to elicit adequate seizures. A measurement of seizure adequacy in electroencephalogram is the postictal suppression. The purpose of this study was to investigate the influence of seizure induction time on the degree of postictal suppression by comparing BIS versus no-BIS monitoring in MST and ECT. METHODS Twenty patients with treatment-resistant depression were randoml…
Measurement of the atmospheric ?µ energy spectrum from 100 GeV to 200 TeV with the ANTARES telescope
2013
Atmospheric neutrinos are produced during cascades initiated by the interaction of primary cosmic rays with air nuclei. In this paper, a measurement of the atmospheric energy spectrum in the energy range 0.1-200 TeV is presented, using data collected by the ANTARES underwater neutrino telescope from 2008 to 2011. Overall, the measured flux is similar to 25 % higher than predicted by the conventional neutrino flux, and compatible with the measurements reported in ice. The flux is compatible with a single power-law dependence with spectral index gamma (meas)=3.58 +/- 0.12. With the present statistics the contribution of prompt neutrinos cannot be established.
Robust Neutrino Constraints by Combining Low Redshift Observations with the CMB
2009
We illustrate how recently improved low-redshift cosmological measurements can tighten constraints on neutrino properties. In particular we examine the impact of the assumed cosmological model on the constraints. We first consider the new HST H-0 = 74.2 +/- 3.6 measurement by Riess et al. (2009) and the sigma(8)(Omega(m)/0.25)(0.41) = 0.832 +/- 0.033 constraint from Rozo et al. (2009) derived from the SDSS maxBCG Cluster Catalog. In a ACDM model and when combined with WMAP5 constraints, these low-redshift measurements constrain Sigma m(v) < 0.4 eV at the 95% confidence level. This bound does not relax when allowing for the running of the spectral index or for primordial tensor perturbations…
Cosmological parameters degeneracies and non-Gaussian halo bias
2010
We study the impact of the cosmological parameters uncertainties on the measurements of primordial non-Gaussianity through the large-scale non-Gaussian halo bias effect. While this is not expected to be an issue for the standard Lambda CDM model, it may not be the case for more general models that modify the large-scale shape of the power spectrum. We consider the so-called local non-Gaussianity model, parametrized by the f(NL) non-Gaussianity parameter which is zero for a Gaussian case, and make forecasts on f(NL) from planned surveys, alone and combined with a Planck CMB prior. In particular, we consider EUCLID- and LSST-like surveys and forecast the correlations among f(NL) and the runni…
A search for point sources of EeV photons
2014
Measurements of air showersmade using the hybrid technique developed with the fluorescence and surface detectors of the Pierre Auger Observatory allow a sensitive search for point sources of EeV photons anywhere in the exposed sky. A multivariate analysis reduces the background of hadronic cosmic rays. The search is sensitive to a declination band from −85º to +20º, in an energy range from 1017.3 eV to 1018.5 eV. No photon point source has been detected. An upper limit on the photon flux has been derived for every direction. The mean value of the energy flux limit that results from this, assuming a photon spectral index of −2, is 0.06 eV cm−2 s−1, and no celestial direction exceeds 0.25 eV …
Discovery of off-axis jet structure of TeV blazar Mrk 501 with mm-VLBI
2016
Context. High-resolution millimeter wave very-long-baseline interferometry (mm-VLBI) is an ideal tool for probing the structure at the base of extragalactic jets in detail. The TeV blazar Mrk 501 is one of the best targets among BL Lac objects for studying the nature of off-axis jet structures because it shows different jet position angles at different scales. Aims. The aim of this study is to investigate the properties of the off-axis jet structure through high-resolution mm-VLBI images at the jet base and physical parameters such as kinematics, flux densities, and spectral indices. Methods. We performed Very Long Baseline Array (VLBA) observations over six epochs from 2012 February to 201…
All-particle cosmic ray energy spectrum measured with 26 IceTop stations
2012
Astroparticle physics 44, 40 - 58 (2013). doi:10.1016/j.astropartphys.2013.01.016
Gamma-Ray Flares from Mrk421 in 2008 observed with the ARGO-YBJ detector
2010
In 2008 the blazar Markarian 421 entered a very active phase and was one of the brightest sources in the sky at TeV energies, showing frequent flaring episodes. Using the data of ARGO-YBJ, a full coverage air shower detector located at Yangbajing (4300 m a.s.l., Tibet, China), we monitored the source at gamma ray energies E > 0.3 TeV during the whole year. The observed flux was variable, with the strongest flares in March and June, in correlation with X-ray enhanced activity. While during specific episodes the TeV flux could be several times larger than the Crab Nebula one, the average emission from day 41 to 180 was almost twice the Crab level, with an integral flux of (3.6 +-0.6) 10^-1…